The FAKRA Outer is the third phase of the Mecal process for crimping FAKRA wires. The machine is comprised of a P107C, an electrical-pneumatic control panel with PLC and a special mini applicator.
P107C The P107C press is standard. This application is the final phase in a semi-automatic process but it can be combined with an automatic line. The press also includes the TT1000 Crimp Force Analyzer.
MRSP OUTER Left-side feed Restyling Mini Applicator with pneumatic terminal feeding. It connects to the press with a Mecal STD baseplate, shut height at bottom dead center of 135.8mm. The continuous adjustment head offers a resolution of 0.01mm to control the crimping height on the SLEEVE and on the insulation. The machine includes the following control sensors:
- OUTER terminal locking on crimping supports
- linear positioning / OUTER terminal presence on crimping supports
- reel end
- forward motion of terminal from the band
- Inner positioning inside the OUTER
The mini applicator includes an electrical connection and two panel-controlled pneumatic connections in order to facilitate removal from the press to allow maintenance or replacement of spare parts.
CENTRAL CONTROL UNIT The electro-pneumatic central control unit is located on the right side of the press and it uses a panel electrical connection and two pneumatic connections to interface with the mini applicator and the press. The MECAL's own PLC controls the functions of the mini applicator and can also be set to execute the STEP BY STEP operating cycle. The version for automatic machines includes a connection with IN – OUT signals required based on need.
SEMIAUTOMATIC OPERATING CYCLE The operating cycle begins by using a pedal and includes the following operating steps, in order:
- Locking the terminal on crimping supports with dual control through sensors and three available operating conditions:
a) terminal lock sensor ON; linear positioning sensor ON – the machine is ready for the next step (terminal is present and in alignment) b) terminal lock sensor OFF, linear positioning sensor OFF the machine is in KO and enters into the ALARM mode (terminal present but not in alignment) c) terminal lock sensor ON, linear positioning sensor OFF the machine is restored and makes another movement forward (terminal absent from the reel)
- separation of the terminal from the band
- movement of the terminal toward the upper part of the mini applicator. Dedicated centering units guide the terminal along the INNER positioning
- insertion of centering clamps for the INNER
- closure of the centering clamps for the INNER on the INNER positioning
- waiting for insertion of coaxial wire with the INNER
- insertion of coaxial wire with Inner on positioning support
- activation of the INNER positioning sensor
- closure of the locking clamps of the coaxial wire
- opening and movement of the INNER centering clamp
- movement of the OUTER terminal from the upper part of the mini applicator to its original position with the following controls via sensors:
a) if the INNER position sensor stays ON during movement, the machine is OK for the next step (point 12) b) if the INNER position sensor turns OFF during movement (after verifying any abnormality on the positioning), the system is released and starts from point 3, giving the operator the opportunity to remove the coaxial wire and check the problem. The coaxial wire is NOT damaged or discarded.
- crimping through the standard cycle of the press
- opening the terminal locking system
- opening the coaxial wire locking
- forward movement of the successive terminal
|
|
ID |
FAKRA Outer
|
CODE |
BB220000011729
|
AIR PRESSURE |
5 - 7 BAR
|
DIMENSIONS mm |
W280xH880xD310
|
DIMENSIONS (") |
W11"xH34,65"xD12,2"
|
WEIGHT |
85 kg (189 lb)
|
POWER |
0.55KW (0.75HP) monophasic
|
POWER SUPPLY |
220V 50~60Hz
|
WIRE SECTION |
RG174, RTK031, RG58/59
|
MAX STRIPPING LENGTH |
16mm (0,63")
|
END MACHINING LENGTH |
max 3mm (max 0.12")
|
CYCLE TIME |
approx 3,4 sec
|
|